球盟会体育网址|网站拥有全球最顶尖的原生APP,每天为您提供千场精彩体育赛事,球盟会体育网址|网站更有真人、彩票、电子老虎机、真人电子竞技游戏等多种娱乐方式选择,球盟会体育网址|网站让您尽享娱乐、赛事投注等,且无后顾之忧!

              "
              Location:PRODUCTS >> Drain valve >> Inverted barrel steam traps
              Inverted barrel steam traps
              Model: 981
              Nominal diameter: DN15 ~ 65mm
              Nominal: PN0.01 ~ 1.6MPa
              Operating temperature: ≤350 ℃
              Main material: Forged steel, stainless steel, titanium steel, chromium molybdenum steel, low temperature steel
              Operation: manual
              Design specifications : GB / T 9093
              Construction length: GB / T 12250
              Threaded connection: ISO 228
              Flange connection: JB / T 79, GB 9113, ANSI B16.34
              Test and Inspection: GB / T 13927

              Basic information
               How it works:  Inverted hanging (set) bucket steam trap It is the use of condensed water and steam density difference principle of work, the internal structure is connected by the lever system upside down bucket to overcome the steam pressure switch inverted bucket trap inside is an inverted bucket for the liquid Bit-sensitive parts, inverted bucket opening down. When the device is started, air and low temperature condensate appear in the pipe. At this time, the trap is fully open, and the air and low temperature condensate are quickly discharged, and the device quickly raises the temperature. When steam enters the inverted bucket, the inverted bucket produces upward buoyancy, and the inverted bucket connects the lever to drive the valve to close the valve. Inverted bucket has a small hole to open the air automatically, as part of the steam discharged from the hole, the other part of the steam condensate, inverted bucket loses its buoyancy to sink, inverted bucket connected to the valve lever to open the valve lever. When the steam into the inverted bucket again, the valve closed again, work cycle, intermittent drainage.
               

              Nominal pressure
              PN16
              PN25
              PN40
              Anti-air resistance function
              Vents self-control
              Vents self-control
              Vents self-control
              PMA maximum allowable pressure 1.6MPa@38 ℃
              2.5MPa@38 ℃ 4.1MPa@38 ℃
              PMO maximum working pressure 1.3MPa@315 ℃ 2.0MPa@200 ℃ 2.5MPa@200 ℃
              TMA maximum allowable temperature
              425 ℃@1.1MPa 425 ℃@1.1MPa 425 ℃@2.6MPa
              TMO maximum operating temperature
              425 ℃@1.1MPa 425 ℃@1.1MPa 425 ℃@2.6MPa


              Product number Nominal diameter (mm) Connection method Working pressure (MPa) The maximum
                   allowable
              temperature
              Dimensions Weight (kg)
              L H1 H2 W
              980 15-20 Thread 0.01-1.0 350 128 76 70 96 2.2
              981 15-25 0.01-1.6 350 128 76 100 96 2.8
              982 15-25 0.01-1.6 350 170 96 137 145 7.0
              983 25-32 0.01-1.6 350 202 121 193 180 14.0
              884 32-40 0.01-1.6 350 235 152 212 203 23.0
              885 32-50 0.01-1.6 350 260 232 222 228 26.0
              816 50 0.01-1.6 350 302 214 242 202 42.0
              881F 15-25 Flange 0.01-1.6 350 195 76 100 96 5
              882F 20-25 0.01-1.6 350 230 96 137 145 10
              883F 25-32 0.01-1.6 350 270 121 193 180 18
              983F 40-50 0.01-1.6 350 320 121 193 180 18
              884F 32-50 0.01-1.6 350 320 152 212 203 27
              885F 40-50 0.01-1.6 350 350 232 222 228 29
              816F 65-80 0.01-1.6 350 400 214 242 302 45
              QQ
              0086 021-69755272
              qrCode